Mark-3 Testing: Ease of Pull-Start

By Gary Da Silva

Product Manager at WATERAX. Expert in market needs and product capability.

In a survey on the aspects of the MARK-3® pump that needed improvement, ease of start was the second most requested improvement after weight reduction. Many firefighters expressed trouble starting a MARK-3® with one arm, either due to a lack of strength or fatigue. To compensate, some firefighters stand on the base to hold the pump down. But, because there’s little space on the base to stand on, this presents a risk of injury from muffler burns. Failing to start a MARK-3® pump in the field can be a source of wounded pride. Some respondents reported anxiety when starting the pump for fear of looking weak or unqualified.

See also  Plan Ahead: Get Your Free WATERAX 2018 Calendar

Given this feedback, our team set out to improve this aspect of the MARK-3® pump by significantly reducing the force required to pull-start the MARK-3® Watson Edition.
The addition of a foothold for steady pull-start—positioned away from the muffler—improves stability while ensuring firefighter safety.

Firefighters who had the chance to pull-start the MARK-3® Watson Edition during the tour were delighted by how easy it was. In order to quantify exactly how much easier it was to start, our engineering team put together a formal test plan.

Results demonstrated that the MARK-3® Watson Edition required 40% less force than its predecessor and generated 3 times the rotation speed, resulting in a much easier pull-start. Below are the results of the test.

See also  Vallfirest: vft3 Wildland Fire Helmet

Results & Observations

The pulls on both pump units were completed following the same procedure with the test setup shown in the photograph to the right.

The pull force, rotation speed and total number of revolutions completed were compiled and listed in the tables below.

WaterAx pull test results

Topics

Newslettter

Subscribe to Our Monthly Newsletter

Stay in the loop with our wildland newsletter.

By Gary Da Silva Product Manager at WATERAX. Expert in market needs and product capability. In a survey on the aspects of the MARK-3® pump that needed improvement, ease of start was the second most requested improvement after weight reduction. Many firefighters expressed trouble starting a MARK-3® with one arm, either due to a lack […]

Get The Wildland Firefighter Newsletter

Related Articles

Wildfires Burn Thousands of Acres on Tribal Lands in ND

Wildfires Burn Thousands of Acres on Tribal Lands in ND

By JACK DURA Associated Press BISMARCK, N.D. (AP) — Crews have been fighting at least 16 wildfires throughout North Dakota in the last several days, including several large fires still burning Tuesday across wooded areas and grasslands on the Turtle Mountain...

NC Fire Grows to 1,300 Acres; Burn Ban Implemented

NC Fire Grows to 1,300 Acres; Burn Ban Implemented

Martha Quillin - The Herald (Rock Hill, S.C.) (TNS) A wildfire in Brunswick County that started Friday, May 2, is the largest of dozens of fires crews are working to contain across North Carolina. Weekend rains helped with some of the fires, but much of the state...

NJ Teen Is Second Suspect Arrested in Massive Ocean County Wildfire

NJ Teen Is Second Suspect Arrested in Massive Ocean County Wildfire

Muri Assunção - New York Daily News A New Jersey teenager has been arrested in connection with a massive wildfire that has burned more than 15,000 acres in Ocean County, prosecutors announced Friday. The 17-year-old male juvenile, who hasn’t been named because of his...